Welcome To Langton device Co., Ltd
EMERSON Magnetic Flowmeters
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
  • Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
  • Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
  • Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
  • Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
  • Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters

Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters

Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters A dual-compartment transmitter h……

Description

Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters

A dual-compartment transmitter housing provides isolation from the external environment. Advanced diagnostics and through-the-glass Local Operator Interface offer unparalleled process insight.

Features

Ensure uninterrupted process monitoring by utilizing Smart Meter Verification, which continuously assesses meter health and performance.

Protect against moisture ingress with a dual-compartment transmitter housing, maintaining the integrity of the meter.

Enhance process management with advanced Digital Signal Processing, optimizing performance and accuracy.

Achieve optimal control even in noisy applications through the High Process Noise diagnostic and Selectable Coil Drive Frequency options.

Minimize issues and false readings when the pipe is empty with the Tunable Empty Pipe diagnostic.

Efficiently verify installation integrity with the Ground and Wiring Fault Detection diagnostic, enabling quick identification of any faults.

Simplify adjustments in hazardous environments without the need to remove the cover, thanks to optical switches for configuration.

Reduce inventory and ensure a consistent interface for any magnetic flow meter sensor with the universal transmitter capabilities, streamlining operations.

Specifications

Sensor compatibility
Compatible with Rosemount 8705, 8711, and 8721sensors. Compatible with AC and DC powered sensors ofother manufacturers.
Transmitter coil drive current
500mA
Flow rate range
Capable of processing signals from fluids that are travelingbetween 0.04 and 39 ft/s (0.01 to 12 m/s) for both forwardand reverse flow in all sensor sizes. Full scale continuouslyadjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits
Process liquid must have a conductivity of5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply
90 – 250VAC, 50/60Hz or 12 – 42VDC
Line power fuses
90-250VAC systems
1A, 250V, I2t, 1.5 A2s Rating, Fast ActingBussman AGC-1, Littlefuse 31201.5HXP
12-42VDC systems
3 Amp, 250V, I2t, 14 A2s Rating, Fast ActingBel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
Line power fuses
15W maximum – DC
40VA maximum – AC
Switch-on current
AC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC